1.
Appl Radiat Isot ; 200: 110945, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37515859

RESUMO

The Bureau International des Poids et Mesures (BIPM) is developing a new transfer instrument to extend its centralized services for assessing the international equivalence of radioactive standards to new radionuclides. A liquid scintillation counter using the triple/double coincidence ratio method is being studied and tested in the CCRI(II)-P1.Co-60 pilot study. The pilot study, involving 13 participating laboratories with primary calibration capabilities, validated the approach against the original international reference system based on ionization chambers, which has been in operation since 1976. The results are in agreement and an accuracy suitable for purpose, below 5×10-4, is achieved. The pilot study also reveals an issue when impurities emitting low-energy electrons are present in the standard solution, which have a different impact on liquid scintillation counting compared to other primary measurement methods.

2.
Appl Radiat Isot ; 155: 108837, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31655349

RESUMO

The results of an international comparison of activity measurements of a solution of 231Pa are reported and analysed. Prior to this, no known standardisation of 231Pa by activity measurement had been carried out. The comparison was run in 2017-2018 involving eight laboratories, and returned results with no identifiable inconsistencies between methods or laboratories. The results, including one mass determination, gave a231Pa activity concentration of 41.461(48) kBq g-1 and a231Pa atom concentration of 61.48(23) × 1015 atoms g-1, from which a half-life value of 32 570(130) years was derived.

3.
Artigo em Inglês | MEDLINE | ID: mdl-32165777

RESUMO

A 231Pa reference material has been characterized for amount of protactinium. This reference material is primarily intended for calibration of 233Pa tracers produced for 235U-231Pa model age measurements associated with nuclear forensics and nuclear safeguards. Primary measurements for characterization were made by isotope dilution mass spectrometry of a purified 231Pa solution using a 233Pa isotopic spike. The spike was calibrated by allowing multiple aliquots of the 233Pa spike solution to decay to 233U and then measuring the ingrown 233U by isotope dilution mass spectrometry using a certified uranium assay and isotopic standard as a reverse-spike. The new 231Pa reference material will simplify calibration of the 233Pa isotope dilution spikes, provide metrological traceability, and potentially reduce the overall measurement uncertainty of model ages.

4.
Appl Radiat Isot ; 134: 257-262, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28709738

RESUMO

A comparison of calculations of the activity of a 3H2O liquid scintillation source using the same experimental data set collected at the LNE-LNHB with a triple-to-double coincidence ratio (TDCR) counter was completed. A total of 17 laboratories calculated the activity and standard uncertainty of the LS source using the files with experimental data provided by the LNE-LNHB. The results as well as relevant information on the computation techniques are presented and analysed in this paper. All results are compatible, even if there is a significant dispersion between the reported uncertainties. An output of this comparison is the estimation of the dispersion of TDCR measurement results when measurement conditions are well defined.

5.
Appl Radiat Isot ; 109: 30-35, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26585641

RESUMO

An informal bilateral comparison of (14)C liquid scintillation (LS) counting at the National Research Council of Canada (NRC) and the National Institute of Standards and Technology (NIST) has been completed. Two solutions, one containing (14)C-labeled sodium benzoate and one containing (14)C-labeled n-hexadecane, were measured at both laboratories. Despite observed LS cocktail instabilities, the two laboratories achieved accord in their standardizations of both solutions. At the conclusion of the comparison, the beta spectrum used for efficiency calculations was identified as inadequate and the data were reanalyzed with different inputs, improving accord.

6.
Anal Chem ; 87(8): 4495-502, 2015 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-25826198

RESUMO

A novel and sensitive approach for the accurate and precise determination of Pb in environmental samples is presented using transition metal ion-assisted photochemical vapor generation (PVG) for sample introduction with multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) detection. A significant improvement in PVG efficiency of lead is achieved in the presence of transition metal ions (Co(2+) and Ni(2+)) in solutions of 5% (v/v) formic acid. The determination of Pb in digests of sediment or soil samples is readily achieved due to coexisting transition metal ions which facilitate the PVG reaction. The method detection limit of 0.005 ng g(-1) (3σ) using external calibration is comparable to that obtained using hydride generation (HG) ICPMS. However, PVG methodology is simpler, results in lower blanks, and avoids unstable reagents. The accuracy of the proposed method was demonstrated by analysis of several environmental certified reference materials (CRMs; SLRS-5 and SRM1640a river water CRMs and MESS-3, MESS-4, and SRM2702 sediments) with satisfying results. High precision of determination (<0.4% RSD) of Pb in river water and sediments was realized on the basis of isotope dilution calibration.